PbS Non-Cooled Photoconductive IR Detectors
Room Temperature Infrared Detectors with Enhanced Stability & Resistance to High Temperatures in the 1 – 3.3 um Wavelength Band
Ambient Temperature: | +25°C |
Detector Operating Temperature | +25°C |
Standard Specifications – Electrical Detectors tested using 50 V/mm across the detector and a one MegOhm load resistor in series. |
||||
Minimum | Typical | Maximum | Units | |
Wavelength of Max. Response | 2.2 | 2.4 | µm | |
D*(λpk, 630 Hz, 1 Hz) | 8.0 x 1010 | 1.0 x 1011 | cm Hz1/2 w-1 | |
Element Resistance (Dark) | 0.2 | 1.0 | 3.5 | MegOhm |
Time Constant (not typically measured) | 100 | 400 | µsec | |
Rated Element Temperature | +65 | °C |
For square or rectangular element sizes and/or packages not listed, please contact us: (707) 620-0160, Info@irmatl.com
When using the table below, remove parenthesis and insert appropriate designation for package type in the space. Example: 3 for TO-3, 5 for TO-5, 8 for TO-8.
Model Number | Element Size (mm) |
Responsivity (lpk, 630) v/w | Standard Package Options | |
Minimum | Typical | |||
A1-( ) | 1 x 1 | 530,000 | 800,000 | TO-5, TO-8 |
A2-( ) | 2 x 2 | 270,000 | 400,000 | TO-5, TO-8 |
A3-( ) | 3 x 3 | 260,000 | 170,000 | TO-5, TO-8 |
A6-8* | 6 x 6 | 90,000 | 140,000 | TO-8 |
A10-3* | 10 x 10 | 50,000 | 75,000 | TO-3 |
* Minimum D*(lpk, 630, 1) >7.0 x 1010 cm Hz1/2 w-1* ** Minimum D*(lpk, 630, 1) >6.0 x 1010 cm Hz1/2 w-1* |
||||
A1-5(M)-L*** | 1×1 with ½ ball lens | 2,000,000 | 2,400,000 | TO-5 with ½ ball |
A1-5(M)-FL**** | 1×1 with full ball lens | 6,000,000 | 7,20,000 | TO-5 with full ball |
***Minimum D*( λpk,630, 1) >2.5.0 x 1011 cm Hz1/2 w-1>7.0 x 1010 cm Hz1/2 w-1* ****Minimum D*( λpk,630, 1) >6.0 x 1011 cm Hz1/2 w- |
- To specify thermistor option for all TE cooled detectors, add the suffix -T or -TC (calibrated) to the model number.
Learn More About Our Model Numbers:
- Part Number Designation: http://irmatl.com/part-number-designation-2/